Dear Santosh,You know, the fire extinguishers work on pressure, so small fire extinguishers like 2 kg or 5 kg have small cartridges or compressed air for pressure. It may empty (cartridge and compressed air) without use, so fire extinguisher vendors keep a minim...

Refilling Procedures Of Fire Extinguisher(17/Feb/2014)

Refilling of fire extinguishers need not be done every year. As per IS: 2190, as mentioned in the above schedule, if the fire extinguisher is maintained properly (monthly & quarterly routines), it can be refilled every three years. Agencies maintaining fire exti...

Refilling Procedures Of Fire Extinguisher(17/Feb/2014)

Dear Santosh,The refilling period for any fire extinguisher is 1 year. In a no-use condition, if you use any fire extinguisher for training purposes, then you may refill it within 8-10 days. The fire agency uses two kinds of slips on fire extinguishers. One is f...

Refilling Procedures Of Fire Extinguisher(17/Feb/2014)

Dear All,Please help clarify my doubts regarding the procedures for refilling fire extinguishers. We utilized our 2 Kg (Capacity) ABC Type fire extinguisher for training purposes in February 2013 and had it refilled in the same month. However, according to IS 21...

Dear Sir,We have a 30,000 sq ft food factory with 2 floors. I want to know how many fire extinguishers are installed/maintained in the factory area under applicable Acts/Rules/laws. Is it compulsory to install a fire hydrant system for us? The total height of th...

Dear Sir,Can we use a stand for keeping a fire extinguisher? Is there any standard for this?

Fire Extinguisher Stand - Any Standard For This?(6/Apr/2017)

Fire extinguishers can be kept at specified locations where they are clearly visible and easily accessible. They should be placed so that they do not fall and create hindrance in walkways or exit ways. Every fire extinguisher comes with a set of standard instruc...

Fire Extinguisher Stand - Any Standard For This?(6/Apr/2017)

No one of the auditors objected to keeping the extinguisher on the stand and instructed that it should be placed at least 750 mm above ground level. Furthermore, the stand should not be used.

Fire Extinguisher Stand - Any Standard For This?(6/Apr/2017)

Dear BanraviGreetings of the day !!!!!!OSHA requires that the employer shall mount portable fire extinguishers so they are accessible to employees. There is no height requirement listed. However, in OSHA’s e-Tool for Evacuation Plans and Procedures, the agency s...

Fire Extinguisher Stand - Any Standard For This?(6/Apr/2017)

Dear BANRAVI,I don't think only a stand is required. Firstly, you have to conduct a Fire/Safety precaution Survey from a competent Authority, e.g., Fire Dept, Safety Institutions, DISH. They will notify what type, where, how many, location-wise, and the availabi...